ALL PRODUCTS
RS232 Landline Phone PCB Board
The HZ-TB01D RS232 landline phone PCB board combines two-wire analogue telephone communication with standard RS232 command control for OEM hands-free telephones and intercoms.
True full-duplex audio, three speed-dial inputs and standard keypad, LCD and hook-switch interfaces support industrial and elevator communication terminals. The handset connector is reserved in hardware and requires corresponding firmware.
The main telephone circuit is line-powered. A 7–12 V DC auxiliary input supports the loudspeaker or warning lamp; use 12 V DC when connecting the 2 W / 8 Ω loudspeaker or a 12 V warning lamp.
Key Features
Standard RS232 Control
Integrate command communication through a standard RS232 electrical-level interface alongside a two-wire analogue telephone line.
Full-duplex Hands-free Audio
Current voice operation supports true full-duplex hands-free communication, with microphone and 2 W / 8 Ω loudspeaker connections.
Three Speed-dial Inputs
PTT1, PTT2 and PTT3 connections support speed-dial buttons. Keypad, LCD and hook-switch interfaces are standard.
Line Power & Auxiliary DC
The main telephone circuit uses analogue line power. Use a 12 V DC auxiliary supply for the 2 W loudspeaker or 12 V warning lamp.
Call Control & Optional Output
Call-duration limitation and automatic hang-up upon busy-tone detection are standard. Dry-contact output is optional.
OEM Integration Options
Project-based RS232 commands, calling logic, connectors, cables and documentation can be configured. Handset operation requires corresponding firmware.
Technical Specifications
| Parameter | Specification |
|---|---|
| Model | HZ-TB01D |
| Product Type | RS232-controlled analogue telephone PCB |
| Primary Application | Hands-free analogue telephone and intercom integration |
| Communication | Two-wire analogue telephone line |
| RS232 Interface | Command communication; standard RS232 electrical level |
| Main Power Supply | Powered by the analogue telephone line |
| Auxiliary DC Input | 7–12 V DC; use 12 V DC for the 2 W / 8 Ω loudspeaker or 12 V warning lamp |
| Line Feeding Voltage | 33–60 V DC |
| Dialling Method | DTMF tone dialling |
| Voice Mode | True full-duplex hands-free communication |
| Reserved Handset Interface | Hardware connector reserved; corresponding firmware required |
| Keypad / LCD / Hook-switch | Supported as standard |
| Speed-dial Inputs | 3: PTT1 / PTT2 / PTT3 |
| Standard Call Functions | Call-duration limitation; automatic hang-up upon busy-tone detection |
| Dry-contact Output | Optional |
| Loudspeaker Connection | 2 W, 8 Ω |
| Ringing Sound Level | >80 dB(A) at 1 m; 2 W speaker |
| DTMF Frequency Groups | Low: 697 / 770 / 852 / 941 Hz; high: 1209 / 1336 / 1477 Hz |
| Frequency Deviation | −1.5% to +1.5% |
| Call Transmission Index | At 5 km: SLR <12 dB; RLR <−1 dB; STMR >10 dB |
| Output Impedance | 600 Ω |
| Operating Temperature | −40°C to +85°C |
| Relative Humidity | 10%–95% RH |
| Atmospheric Pressure | 86–106 kPa |
| Reliability | MTBF: 100,000 hours; MTTR: 2 hours |
| PCB Dimensions | 98 × 70 × 15 mm |
| Mounting-hole Spacing | 80 × 50 mm |
| Net Weight | 0.23 kg per PCB |
| Gross Weight | 7.2 kg per 30-piece carton |
| Carton Quantity | 30 pcs/carton |
| Carton Dimensions | 370 × 300 × 150 mm |
| Packing Type | Carton box |
| Warranty | 12 months of defect warranty by the manufacturer |
Integration notice: During PCB testing and installation, avoid touching metal parts directly by hand to prevent short circuits or PCB damage. Handset operation and optional outputs depend on the approved hardware and firmware configuration.
Dimensions & Mounting
Customization & Project Support
Enclosure & AppearanceCoordinate PCB integration, branding and custom labels for the intended telephone enclosure and project.
Calling & ConfigurationSpecify approved RS232 commands, speed-dial functions and call-control logic. Handset operation requires corresponding firmware.
Interface & InstallationDiscuss connectors, cables, buttons, handset, warning lamp, LED and optional dry-contact requirements.
Documentation & PackagingRequest custom labels, product specifications, user manuals and package markings. Standard packing is 30 PCBs per carton.
Applications
For OEM integration into analogue communication equipment:
- Emergency telephones and industrial help points
- Weatherproof and vandal-resistant telephone terminals
- Prison and public telephones
- Emergency and elevator intercom terminals
- Cleanroom communication equipment
- Customized analogue telephone systems
Explore Related Products
REQUEST A QUOTE
Shenzhen HeoZ Technology Co., Ltd.
Email:
Pricing & Project Support:
sales1@heoztech.com
General Contact:
info@heoztech.com
Mobile / WhatsApp:
Pricing & Project Support: +86 199 2645 9261
Technical Support: +86 181 2372 5966
Address: Room 601, Building 2, Jingyefang Industrial Park, No. 1 Fengxing Lane, Fenghuang Community, Fuyong Street, Bao’an District, Shenzhen, China 518103.
Pricing & Project Support: sales1@heoztech.com
WhatsApp: +86 199 2645 9261